Chapter 3 - Printer Operation

32

Advanced Entry Calibration (continued)

Step

Action

Displayed Message

Comment

L

Use the buttons to set the Gain
Number determined in the
previous step. Press ENTER to
enable the setting.

TRAN SENSOR GAIN

yyy (0 - 31)
18

This example uses Gain Number
18.

M

Complete a table (see example
below) using new measurements,
as follows:

(A) Raise the Printhead Assembly.
Place the label over the Media
Sensor then lower and latch the
Printhead Assembly. Record the
sensor reading as P.

(B) Raise the Printhead Assembly.
Place the liner, notch, or mark
over the Media Sensor then lower
and latch the Printhead Assembly.
Record the sensor reading as G (or
M).

(C) Raise the Printhead Assembly.
Remove all media from the Media
Sensor then lower and latch the
Printhead Assembly. Record the
sensor reading as E.

TRAN SENSOR GAIN

yyy (0 - 31)
18

Where “yyy” is a numerical value
representing the current sensor
reading.

The re-sampled values may

differ from those previously
noted. This is normal; do not
readjust the Media Sensor.


Selected Gain Table

Gain Number

Paper

Gap (or Mark)

Empty

18 173 42 9

Advertising