Chapter 3 - Printer Operation

31

Advanced Entry Calibration (continued)

Step

Action

Displayed Message

Comment

J

Use the buttons to increment the
Gain Number by one. Record the
TOF Value. Repeat this process for
each Gain Number.

TRAN SENSOR GAIN

yyy (0 - 31)
01

These are TOF Values, where
“yyy” represents the current
sensor reading.

Sample Calibration Table

Gain Number

Label Value

TOF Value

Difference Value

00 252 248

01 250 245

02 248 234

… … …

31 09 14

Step

Action

Displayed Message

Comment

K

In your sample calibration table,
where both the Label Value and
TOF Value are at least 20, subtract
the amounts and record the result
as a Difference Value (see below).

Identify the largest Difference
Value and the corresponding Gain
Number. This Gain Number will be
used to resample the media.

TRAN SENSOR GAIN

yyy (0 - 31)
31

In this example, Gain Number 18
is chosen because, where both
values are at least twenty, it has
the highest Difference Value.

Sample Calibration Table

Gain Number

Label Value

TOF Value

Difference Value

00 252 248 4

01 250 245 5

02 248 234 14

… … … …

15 188 63 125

16 184 51 133

17 179 38 141

18

174

25

149

19 170 19 N/A

… … … …

31 132 14 N/A