Chapter 3 - Printer Operation

30

Advanced Entry Calibration (continued)

Step

Action

Displayed Message

Comment

H

Raise the printhead assembly then
proceed according to the media
type:

Die-cut – Remove a label or two
from the liner then position the
liner in the Media Sensor. Adjust
the Media Sensor if necessary.

Notched – Position the Media in
the Media Sensor under the notch.

Reflective – Position the Media in
the Media Sensor under the black
mark.

TRAN SENSOR GAIN

31

(0 - 31)


(1) Do not position the Media
Sensor under a perforation; and
if using preprinted media, ensure
the label area placed over the
sensor is free of text, graphics,
lines, etc.


(2) Do not move the Media
Sensor after this step.

I

Lower and latch the Printhead
Assembly.

Using the UP and DOWN Arrow
buttons set the Gain Number to
00.

Record the reading as a TOF Value
for Gain Number 00 in the table.

TRAN SENSOR GAIN

yyy (0 - 31)

00

This is the TOF Value for a gain
setting of 00, where “yyy”
represents the current sensor
reading.

Sample Calibration Table

Gain Number

Label Value

TOF Value

Difference Value

00 252 248

01 250

02 248

… …

31 09