Chapter 4 – Menu System

39

DISPLAYED ITEM

ITEM DESCRIPTION

SENSOR

CALIBRATION

Selects the media sensor calibration method, where:

PERFORM

CALIBRATION

Sets the values via internal printer calculations, as described in the STANDARD

CALIBRATION procedure.

ADVANCED ENTRY

Sets the values via manual entry (typically for hard to calibrate label stocks), as

described in the ADVANCED ENTRY CALIBRATION where:

PAPER SENSOR

LEVEL

Establishes the threshold for the paper value (0 - 255), where 170 is the default

setting.

REFL PAPER

LEVEL

Establishes the threshold for the reflective value (0 - 255), where 170 is the

default setting.

GAP SENSOR

LEVEL

Establishes the threshold for the gap value (0 - 255), where 040 is the default

setting.

MARK SENSOR

LEVEL

Establishes the threshold for the mark value (0 - 255), where 040 is the default

setting.

EMPTY SENSOR

LEVEL

Establishes the threshold for the empty value (0 - 255), where 000 is the default

setting.

TRAN SENSOR

GAIN

Establishes the sensitivity of the transmissive sensor (0 - 31), where 15 is the

default setting.

REFL SENSOR

GAIN

Establishes the sensitivity of the reflective sensor (0 - 31), where 15 is the

default setting.

PRINTHEAD

CLEANING

Controls the automatic cleaning alert and function, where:

CLEAN HEAD
SCHEDULE

Specifies the inch (or centimeter) count at which to clean the printhead, and if
exceeded three times, declare a Head Cleaning Fault. (Note that the specified

count [0 - 200 inches] will be multiplied by one thousand, and that zero [the

default setting] will disable the function.)

CLEAN HEAD

COUNTER

Indicates the number of inches (or centimeters) since a cleaning was last

initiated.

RESET COUNTER

Resets the Clean Head Counter to zero to restart the Clean Head Schedule.

CLEAN HEAD NOW

Initiates the cleaning process and resets the Clean Head Counter.