Chapter 4 – Menu System

51

Communications

The Communications menu contains interface and host control functions:

Serial Port A*

Parallel Port A*

USB Port*

Network Interface*

Host Settings*

Items denoted with an asterisk (*) are only accessible through the Advanced Menu.

The menu selections are defined as follows:

DISPLAYED ITEM

ITEM DESCRIPTION

SERIAL PORT A

Controls the RS-232 communications settings for Serial Port A, where:

BAUD RATE

Sets the serial communication rate, where:

(1200 –
115000 BPS)

9600 BPS

Is the range, in Bits Per Second; and,

is the Default Setting.

PROTOCOL

Sets the data flow control (handshaking) method, where:

BOTH

XON/XOFF and CTS/DTR are used. (Default Setting)

SOFTWARE XON/XOFF

is

used.

HARDWARE

CTS/DTR is used.

NONE

Flow control is not used.

PARITY

Sets word parity, where:

NONE

Parity is not used. (Default Setting)

ODD

Odd parity is used.

EVEN

Even parity is used.

DATA BITS

Sets word length, where:

(7 - 8)

8

A seven or eight bit word is selectable; and,

is the Default Setting.

STOP BITS

Sets the number of stop bits, where:

(1 - 2)

1

One stop or two stop bits are selectable; and,

is the Default Setting.

PARALLEL PORT A

Controls the communication setting for the parallel port, where:

PORT

DIRECTION

Determines if data is returned from the printer, where:

UNI-
DIRECTIONAL

No data is returned; communication is one-way.

BI-

DIRECTIONAL

Data is returned in compliance with IEEE 1284 back-channel operation. (Default

Setting)

An IEEE 1284 bidirectional cable is required.

USB PORT

Controls the communication setting for the USB port

USB DEVICE CLASS Defines the USB port type

PRINTER

Sets the printer for use as a typical Windows printer

CDC

Sets the printer for use with handled PC’s and similar devices

Composite

Combines both Printer and CDC classes. (Defautl Setting)

NETWORK

INTERFACE

Controls the communications settings for the network interface, where:

QUICK SETUP

Controls the communications settings for the network interface, where:

WIRED DHCP

Configures the card for wired connection.

SET FACTORY

DEFAULTS

Resets NIC Adapter parameters to the factory defaults values.