Chapter 4 – Menu System

47

DISPLAYED ITEM

ITEM DESCRIPTION

SET FACTORY

DEFAULTS

Returns the printer settings to the factory-programmed values (except CUSTOM

ADJUSTMENTS and calibrations); or, if selected, to the Factory Setting File, where
selecting YES at the prompt causes the configuration to be restored.

FORMAT

ATTRIBUTES

Defines the manner in which overlapping text and graphics appear when printed,

where:

TRANSPARENT

Intersecting text, images, and bar codes will be printed, for example:

XOR

Intersecting text, images, and bar codes will not be printed, for example:

(Default Setting)

OPAQUE

Intersecting text, images, and bar codes will be printed by obliterating those
formatted first, for example:

LABEL ROTATION

Allows the label format to be rotated 180 degrees before printing, where:

ENABLED Flips

the

format.

DISABLED

Does not flip the format. (Default Setting)

IMAGING MODE

Determines the process used to format labels, where:

MULTIPLE LABEL

Images multiple labels as memory permits to achieve the fastest throughput. If
time-stamping labels, however, the indicated time will reflect the moment of

imaging rather than the actual print time. (Default Setting)

SINGLE LABEL

Images the next label only after the previous label has been printed, providing the

most accurate time-stamps but at a slower throughput rate.

PAUSE MODE

Allows for controlled interactive printing, where:

ENABLED

Requires you to press the PAUSE Key to print each label.

DISABLED

Labels are printed without pausing. (Default Setting)

PEEL MODE

Allows the printer to wait until the Start of Print signal is received (via the optional
GPIO Port) to feed a label, where:

ENABLED

Inhibits the feed function until the Start of Print signal is received.

DISABLED

Feeds the label regardless of the Start of Print signal. (Default Setting)

SECURITY

Allows all or part of the User Interface to be password-protected and for that

password to be modified:

SELECT
SECURITY

Allows password to be set for specific User Interface areas, where:

DISABLED

No password is required for menu access. (Default Setting)

SECURE MENU

Sets a password requirement for User and Advanced menu entry.

MENU AND

TEST

Sets a password requirement for all menu entries.

ADVANCED
MENU

Sets a password requirement for Advanced menu entry. (After enabling this
selection, make it effective by returning the Menu Mode to the User setting; see

above.)

MODIFY

PASSWORD

Modifies the four-digit password required when security is enabled. For

modification, the code must be reentered when prompted to confirm.

To be activated, the password must initially be set to a value other than the default setting

(0000).