IPC-WP Series Service Manual
2.6.3 Operation
Operation
Display
1. Stating
Test
2. Scale No. and Decimal point indication mode
x
Press the [ TARE ] key ON → (1
st
digit flashes)
x
Example: ASIA 3kg (1g) Single range X1=5, X2=4
2.1 Scale No. Setting
x
Press the [ * ] key ON four times (X1=5)
X2
X1
X2
X1
2.2 Decimal point indication Setting
x
Press the [ ZERO ] key ON → (2
nd
digit flashes)
X2
X1
x
Press the [ * ] key ON three times (X2=4)
X2
X1
x
When the C3 mode is required, press the TARE key.
x
When finishing, press the Memory Switch to record
the data to the memory, and enter the Ending Test
Mode.