IPC-WP Series Service Manual
7. Remove the 2 Screws (M6x25) that are
holding the Load cell.
Load Cell
3kg: CZL-6d-C3-5kg-1000
6kg: CZL-6d-C3-10kg-1000
15kg: CZL-6d-C3-25kg-1000
Assembly procedure
1. Adjust the clearance limit by tightening the
screw, spring washer, and flat washer on the
plate support.
2. When you finish adjusting the clearance,
paste the screw lock coagulant.
The clearance limit is shown below.
3. For assembly, perform the disassembly procedure in reverse.
4. After re-assembling all the parts, clear E2ROM and perform settings and span adjustment in C1,
C2, and C3 modes.