Rice Lake Ishida iPC-WP Portable Bench Scales User Manual

Page 33

Advertising
background image

30/32

IPC-WP Series Service Manual

7. Remove the 2 Screws (M6x25) that are

holding the Load cell.

Load Cell

3kg: CZL-6d-C3-5kg-1000

6kg: CZL-6d-C3-10kg-1000

15kg: CZL-6d-C3-25kg-1000

Assembly procedure

1. Adjust the clearance limit by tightening the

screw, spring washer, and flat washer on the
plate support.


2. When you finish adjusting the clearance,

paste the screw lock coagulant.

The clearance limit is shown below.

3. For assembly, perform the disassembly procedure in reverse.

4. After re-assembling all the parts, clear E2ROM and perform settings and span adjustment in C1,

C2, and C3 modes.

M6×25.SW.W

Plate support

Load cell

Advertising