16/32

IPC-WP Series Service Manual

¡Data after E2ROM is cleared

Mode

Data

Item

C1 1

JAPAN

C2

11

Scale No.= 3kg (2g/1g) Multi interval Decimal point indication= " 0"

C3

Zero point and span adjustment value and each approximate value

F 804

Measurement

condition

2.8.2 Error

No.

List

Error No.

Mode

Item

Err1

At power ON

E2PROM unsetting or garbled data

Err2

At power ON

Outside start range

Err3 Test

mode

Outside range where zero point can be adjusted (original A/D
1000 count or less)

Err4

Test mode

(Original A/D 25000 count or more)

Err5 Test

mode

Outside span adjustment possible range (original A/D 33300
count or more)

Err6

Normal mode Original A/D zero count or less

Advertising