Chapter 4 Maintenance

4.1 Disassembly

Procedure

Note

The seal restricts the peel according to the country by a no report and doing as
wanting put it. Follow the relevant procedure for the respective countries.

Caution

The water proof sheet is to maintain the water proofing property. When you remove
the sheet, replace it with a new one.

4.1.1 Case

Disassembly Procedure

&

Assembly Procedure

1. When using dry batteries, remove them before

disassembly or assembly.

When using an AC adaptor, disconnect it before

disassembly or assembly.


2. Remove the weighing platter.


3. Remove the Water proof sheet attached to the

platter bracket.




Caution

When re-assembling the scale, use a new Sheet
protect.
When affixing the new sheet protect, completely
remove the starch left on the bracket.
Otherwise, the water proofing property will be
deteriorated.

4. Remove the 12 M4 nuts.

5. Remove the 4 M4 screws, then remove the

platter bracket.



Platter

Sheet protect

Platter bracket

M4 Nut

M4 Screw

Platter bracket