2 operator settings, 1 display menu, 2 diagnostics menu – Rice Lake OB-350 Loadrunner Series Onboard Weight Indicator User Manual

Page 15: 1 display menu 5.2.2 diagnostics menu

Advertising
background image

Operator Configuration and Diagnostics

11

5.2

Operator Settings

5.2.1 Display Menu

To change the display contrast

1. In MENU, select

Display.

2. Press

(OK).

3. Select

OLED

.

4. Press

(OK).

5. Press

toggle between:

High

Medium

Low

.

6. Press

to confirm setting.

To display version and serial number

1. In MENU, select

Display.

2. Press

(OK)

.

3. Select

Info

.

4. Press

(OK)

5. Firmware version and serial number displays.

6. Press

twice to return to MENU

5.2.2 Diagnostics Menu

To Display Load Cell Diagnostics

lb

1. In MENU, select

Diagnostics.

2. Press

(OK).

3. Select

Cells.

4. Press

(OK).

5. Channel 1 & 2 weight and input mill-Volt readings are displayed. Channel

1 only is the most common setup.

6. Press

twice to return to MENU.

Milli-Volt readings will differ according to the combined tare (empty)
weight and any payload in the body. Load cells should only be checked
when the vehicle is unloaded. Max input reading is 39.625 milli-Volt, this
is approx 10 times more than would be expected.

Note

To Display CAN Diagnostics

Not currently available.

Advertising