4 reverse zero/span – Rice Lake OB-350 Loadrunner Series Onboard Weight Indicator User Manual

Page 28

Advertising
background image

24

OB-350 Operators Manual

7.1.4

Reverse Zero/Span

lb

lb

lb

62000

Reverse Zero/Span is an alternative to Full Span Calibration. The reverse zero/
span is used to perform a simultaneous zero and span calibration with the
vehicle fully loaded. You must be in single channel mode, ch1only.

1. Weigh and record the vehicle fully loaded.

2. Do a normal span cal 1 (actual span figures not important). See

Section 7.1.2

3. Empty the vehicle, weigh and record the TARE weight.

4. In SPAN menu, check and edit the SPAN figure if required but do

not press ‘cal’.

5. In CAL menu, press

to select Zero.

6. Press

Z

S

to activate zero/span. Reverse span figure shown top-right

corner of display.

7. Press

cal

.

8. Press

(OK)

to confirm channel 1 Zero CAL.

9. Press

to return to CAL menu.

Advertising
This manual is related to the following products: