OB-350 Operators Manual

6.8

Inclinometer

lb

On dump trucks and roll off applications, the

LoadRunner

system uses load

pins and a hydraulic pressure transducer to determine a weight value. To
achieve the best accuracy, calibrate the system at the same incline that will be
used for determining the weight value, within ±1-2 degrees.

The inclinometer setup screen shows both the body angle in a numeric value
and absolute angle (abs 0.0). For this application, use the level indicators that
light up for every degree the body is raised.

The numeric value will indicate a negative value as the body is raised. This is
normal. The level to the right will light up one circle at a time.

The inclinometer function allows visual determination of the height the body
achieves to accurately weigh consistently.

6.8.1 Calibrate the Inclinometer

1. Ensure the truck is on a level surface and the body is in the down

position.

2. In MENU, select

Options

.

3. Press

(OK).

4. In OPTIONS menu, select

Inc.

5. Press

(OK).

6. Press

to select

On

.

7. Press

CAL

to calibrate the inclinometer.

8. Press

(OK)

to confirm inclinometer zero.

9. Press

to return to options menu.

Inclinometer screen will be added to the MENU options.