3.3

Electrical Wiring and Data Connections

The OB-350 is fitted with one Power and one Input Channel connector as standard. CANbus, Channel 2 and RS-232 are optional.
Full connector options is shown for illustration.

1

3

2

4

5

6

12B1D4FB

T

Figure 3-3. Rear Panel Identification and Bulkhead Connectors

Pin

Description

1

Input Channel 1, Max +/-39.0625 milli-Volts (also known as analog)

2

Input Channel 2, Max +/-39.0625 milli-Volts (also known as analog)

3

Power Input & Alarm Output

4

CANbus digital input & output

5

RS-232 output for printers and data capture devices (pin 9 = vehicle volts, pin 5 = ground, pin = 2 transmit, pin 3 =
receive)

6

Alpha-numeric unique indicator serial number, also appears on

power-on

SIGNAL channel 1 & 2, socket is FEMALE. – CON 2 & 3 on PCB

Pin 1

BROWN

+ Excitation

5 Volts DC

Pin 2

WHITE

+ Signal

milliVolts from the junction box & loadcells

Pin 3

BLUE

- Excitation

0 Volts

Pin 4

BLACK

- Signal

milliVolts from the junction box & loadcells

POWER & ALARM, socket is MALE – CON 1 on PCB

Pin 1

BROWN

Vehicle voltage

Supply 12V (LCV) or 24V (MCV & HGV)

Pin 2

WHITE

Output 1

12V or 24V

Pin 3

BLUE

Ground

Ground 0 Volts (common)

Pin 4

BLACK

Output 2

12V or 24V

CANbus input and output, plug is MALE – CON 5 on PCB

Pin 1

BROWN

+24V

+24 Volts DC Power Input

Pin 2

WHITE

GND

CAN bus LOW Output

Pin 3

BLUE

CANH

0 Volts Ground

Pin 4

BLACK

CANL

CAN bus HIGH Output