Technical Settings

17

6.5.6

Scoreboard Format 4

(NET / GROSS)

Data is output in the following format:

<STX(1)> <U/S(3)> <CNT(1)> <U/S(5)> <PAYLOAD(3)> <CHK(1)>

STX = 0x01

Start of text

U/S = (3 bytes)

Unspecified – 3 bytes do not use

CNT = hex val

Count – Incremental message count, from 0x00 to 0xFF hex

U/S = (5 bytes)

Unspecified – 5 bytes do not use

PAYLOAD = (3 bytes)

Weight – 3 characters of weight value in hex (note1)

Select the weight value either NET or GROSS in the M350S set-up.

CHK = hex val

Checksum – longitudinal checksum value not including STX

Example:

Messages with weight 18520 kg (0x004858)

01 00 0A 81 BE 01 01 00 01 00 00 48 58 EC

01 00 0A 81 BF 01 01 00 01 00 00 48 58 ED

01 00 0A 81 C0 01 01 00 01 00 00 48 58 EE

01 00 0A 81 C1 01 01 00 01 00 00 48 58 EF

6.5.7

Scoreboard Format 5

Data is output in the following format:

<STX(1)> <SGN(1)> <PAYLOAD(7)> <STA(1)> <ETX(1)>

STX = 0x02

Start of text

SGN = 0x20 or “-“

Sign – space = pos, minus sign = negative

PAYLOAD

Weight – next 7 characters are weight in ASCII

STA = “N”

Status - N represents NET weight

ETX = 0x03

End of text

Example:

(Net weight 15000 kg)

02 20 20 20 31 35 30 30 30 4E 03

(Net weight 5045 kg)

02 20 20 20 20 35 30 34 35 4E 03