Technical Settings

13

6.3

Alarms Menu

6.3.1

Alarm Setpoints

lb

lb
lb

lb
lb

lb
lb

lb

lb

lb

lb

lb

lb

lb
lb

Allows configuration of the audible alarm.

Table 6-1. Alarm Setpoints Menu

Parameter

Choices

Description

Alarm

Alarm ON

Turns alarm on.

Alarm OFF

Turns alarm off.

Output

Output Normal

+12 VDC to power and alarm on power connector.

Output Invert

-12 VDC to power and alarm on power connector.

Gross

Gross PPCO

Not used (custom packer-plate configuration only).

Net Sounder

Alarm will display speaker and beep when net weight
reaches Alm value entered.

Net PPCO

Not used (custom packer-plate configuration only).

Inc Sounder

For use with inclinometers only – activates alarm when
angle reaches above incline (inclinometer setting) in
degrees.

Inc PPCO

Not used (custom packer-plate configuration only).

Gross Sounder

Alarm will display speaker and beep when gross weight
reaches Alm value entered.

Alm

Alarm Weight
Value

Edit value of the net or gross weight for alarm.

Hys

Hysteresis Value

Not currently available.

Trigger

Off

On

2,5,10 seconds – selectable delay prior to alarm
activating in seconds.

6.3.2

Set Alarm

1. In MENU, select

Alarms

.

2. Press

(OK)

3. Two setpoints appear. Select

Alarm 1

.

4. Pressing

(OK)

toggles between

ON

and

OFF

. Select

ON

.

5. Pressing

(OK)

toggles between

Output Normal

and

Output Invert

.

6. Pressing

(OK)

toggles between

Gross-Sounder

,

Net-Sounder

,

Gross-PPCO

or

Net-PPCO

.

7. Select

Alm

. The alarm (sounder or flashing beacon) will activate at

weight displayed. To change target weight, press

edit

and set the alarm

setpoint using techniques in previous steps.

8. Select

HYS

, reset tolerance is edited in lb using techniques in previous steps.

9. Select

Trigger,

then press

(OK)

to toggle between:

OFF

,

2

,

5

or

10

seconds.

10. When all settings are correct, press

(OK)

to confirm.

11. For alarm 2, select

Alarm 2

and repeat steps 7-10.