0 operation, 1 front panel – Rice Lake OB-350 Loadrunner Series Onboard Weight Indicator User Manual

Page 6

Advertising
background image

2

OB-350 Indicator Operator’s Manual

2.0 Operation

The OB-350 indicator has a power button, but it can also be permanently powered through the ignition 9-30 VDC.

Turn ignition on or press the power button and the software version and serial number appear in the 10 second
welcome screen.

The vehicle’s gross weight will then display. Take weight readings when the vehicle is static and on level ground.
An empty vehicle may drift from a true zero by a few pounds, press

ZERO

to return the display to

0

lb

when the

vehicle is empty. For roll off and dump truck installations, raise body three to four degrees using the inclinometer
screen before zeroing or weighing.

2.1

Front Panel

The four symbol keys: square, down arrow, up arrow and circle on the keypad are assigned in both operator and
setup modes, and are used to navigate through the menus as indicated by the text or symbol in the OLED display.
Weight readings are in lb.

Operator Mode

print

13240

lb

zero

menu

A

B

C

D

E

F

net

Figure 2-1. Operator Mode

Key

Description

A

Print key - prints net, gross, time & date in weighing screens when activated.
Acts as an accumulation button in load/deliver mode.

B

When the vehicle is completely empty and in the weighing position, the front panel ZERO or TARE can be used to
adjust the display to read ‘00000’, up to 1100 lb.

C

MENU key - scrolls through’ NET, GROSS, MENU & any options activated.

D

Displayed weight.

E

Shows active function or weighing mode.

F

Power button.

Advertising
This manual is related to the following products: