8 scoreboard format 6, 9 scoreboard format 7 – Rice Lake OB-350 Loadrunner Series Onboard Weight Indicator User Manual

Page 22

Advertising
background image

18

OB-350 Operators Manual

6.5.8

Scoreboard Format 6

Data is output in the following format every 60 seconds:

$GPVWS,<type>,<sgn>,<net>,<gvw>,<alarm1>,<alarm2>,<set1>,<set2>,HHMMSS,DDMTYY*XX

type = 01

Unit type 01 = M350S under body weigher: LOADWEIGH

sgn = “+” or “-“

Sign of Net – plus sign = positive, minus sign = negative

net

Net weight – 5 characters

gvw

Gross Vehicle Weight – 5 characters

alarm1

Alarm 1 set point – 5 characters

alarm2

Alarm 2 set point – 5 characters

Set 1

N = Net, G = Gross: S = Sounder, P = PPCO: 0 = not Activated, 1 = Activated

Set 2

N = Net, G = Gross: S = Sounder, P = PPCO: 0 = not Activated, 1 = Activated

HHMMSS

Hours, Minutes and Seconds

DDMTYY

Day, Month and Year

*XX

Checksum

Example:

Net = 15000kg, gvw = 25000kg, alarm 1 Net sounder at 15500kg, alarm 2 Gross PPCO at 26000kg
$GPVWS,01,+,15000,25000,15500,26000,NS0,GP0,164100,280210*XX

Net = 15900kg, gvw = 25900kg, alarm 1 Net sounder activated at 15500kg, alarm 2 Gross PPCO at
26000kg $GPVWS,01,+,15900,25900,15500,26000,NS1,GP0,164200,280210*XX

6.5.9

Scoreboard Format 7

Data is output in the following format for interface with a BA484D Serial Display:

<CVn,string> Cyclic

Variable

Parameters

n = 1 or 2 Input Variable number, where 1 = net & 2 = gross, string = any 7-bit numeric ASCII string

The <CV> Cyclic Variable is used to update the BA484D display with each variable individually by sending the
numeric value as a simple ASCII string. The syntax is <CVn,string> where n represents the input variable to be
updated (= 1 or 2) and string is the numeric value to be displayed.

Example:

The command <CV1,123456.0> will set the input variable 1 (net) to a value of “123456.”