Func, Test, Unit – Rice Lake MSI9300 PortaWeigh Crane Scale Operator Manual User Manual

Page 13: S list, F °c, Rflist, Total, A-off

Advertising
background image

MSI-9300 Crane Scale™

User Guide Page 13

MEASUREMENT SYSTEMS INTERNATIONAL

Rev 1 7/27/02 for SW Ver 1-1

USER KEY FUNCTION

The TEST/USER key can be programmed to 1 of 6 functions:

1) TEST – Default function. Provides segment test of the display, battery level, and RF Network information.
2) UNIT – Switch between pounds (lb) and kilograms (kg).
3) S LIST – (Scan List) Change displayed channel to the next channel in the CellScale Scan List. Applicable

to multichannel systems only.

4) °F °C – Displays the internal MSI-9300 temperature for 2 seconds.
5) OFF – No function
6) TOTAL – If manual total is enabled, pushing the TEST/USER key will add the current weight to the

Total register. Subsequent pushes will display the totaled weight until Total is reset by returning to zero

(below the total threshold, see the CellScale User Guide for more information on total threshold). If in any

Auto-Total mode, the USER key functions as View Total, displaying the Total Weight for two seconds.

To Set the User Key Function

1

Func

2

T

TARE

test

3

TEST

Unit

3

TEST

S List

3

TEST

°F °C

3

TEST

rFLiSt

3

TEST

OFF

3

TEST

totaL

4

T

TARE

A-OFF

5

0

ZERO

to exit

5

TEST

to select other Main

Setup Menu items.

1) Start the Setup Mode using the procedure on the previous

page.

2) With the display reading “Func” press the TARE (Select)

key. The currently programmed USER key mode will dis-

play flashing.

The example assumes the dejault function TEST is the current USER key
function.

3) Use the TEST (Scroll) key to scroll through the choices.

In this example the TEST key function will be changed to TOTAL.

4) When the desired choice is shown, Press TARE (Select)

to select it.

Pushing TARE (Select) places the displayed function as the USER key func-
tion, and exits the FUNC menu.

5) The next Main Menu item, “A-OFF” will appear. Either

select another Setup procedure with the TEST (Select) key,

or return to weighing mode by pushing ZERO (Exit).

AUTOMATIC OFF

The MSI-9300 can be set to turn itself off in periods of inactivity by enabling the Automatic Off feature. The

Auto Off timer is reset whenever a button is pushed or weight changes. There are 4 settings:

1) OFF – Feature disabled
2) 0.16 hr – MSI-9300 will turn off in approximately 10 minutes
3) 0.5 hr – MSI-9300 will turn off in ~30 minutes
4) 1 hour – MSI-9300 will turn off in ~1 hour.

Advertising