Appendix – specifications & dimensions – Rice Lake MSI9300 PortaWeigh Crane Scale Operator Manual User Manual

Page 31

Advertising
background image

MSI-9300 Crane Scale™

User Guide Page 31

MEASUREMENT SYSTEMS INTERNATIONAL

Rev 1 7/27/02 for SW Ver 1-1

APPENDIX – SPECIFICATIONS & DIMENSIONS

HARDWARE OVERVIEW

Electronics
• µC Board: 6 layer SMD, AM186ESLV based w/ Flash Memory – 512kbytes of Flash Program Memory,

512kbytes of non-volatile RAM.

• Power Supply / I/O Board: power regulation and I/O for MM – Input range 10-16V. Optional direct AC

board 90-260VAC.

• 2 Channel A/D Board: 4 layer SMD, 24bit A/D.
• Highly integrated Radio Modem: 2.4GHz Spread Spectrum. Protected Antenna.
• Display Board: 4 Layer SMD with six 1.2” (30mm) digits and 14 backlit annunciators.

Housing
• Alodined Cast Aluminum. Double O-ring gasketed. NEMA 4, IP66

Load Train
• Load Cell: 4340 Aircraft Quality Steel
• Industry Standard Lifting Eyes and Bottom Hooks

GENERAL FEATURES

Channels 1-4 – Scale Input Channels
• Internal Load Cell connected to Channel 1. Optional additional scale inputs by special order for multipoint

lift situations.

Channel 5

Channel 5 allows remote access to inputs on remote Slave CellScales

Channel 6

Channel 6 is math calculations. Up to 8 separate math channels can be used to combine conversions from

multiple scale channels. Supported functions are: multiply, divide, add, subtract, absolute value, square

root, and constants. Multiple levels of parentheses are available for any scaling or channel data manipula-

tion formulas.

Excitation

5 V (+5V relative to ground). Current limited and over-voltage protected to Factory Mutual standards. AC

(switched DC) or DC excitation.

Radio Link

Frequency Hopping Spread Spectrum in 64 channels @ 2.4 GHz. Allows 64 collocated networks of scales

and peripheral devices (MSI Models MSI-9020, MSI-9750A, MSI-9850, MSI-3750CS, etc.).

Calibration

Via RF or Input Comm Port. Calibration is accomplished through a computer program residing on any

computer. The calibration program is user friendly, with menus that are easy to use on a full graphics

screen. Calibration is also available using the MSI-3750CS, MSI-9850 or MSI-9750A Meters. Seal can be

provided on front panel in Legal-For-Trade systems.