Page 14 MSI-9300 Crane Scale™

User Guide

MSI-9300 Porta-Weigh+ Crane Scale

To Setup Automatic Off

1

Func

2

TEST

a-Off

3

T

TARE

OFF

4

TEST

0.16 hr

4

TEST

0.50 hr

4

TEST

1 hour

5

T

TARE

Unit

6

0

ZERO

to exit

6

TEST

to select other Main

Setup Menu items.

1) Start the Setup Mode using the procedure on page 12.

2) Use the TEST (Scroll) key to scroll to “A-OFF”.

3) With the display reading “A-OFF” press the TARE

(Select) key. The currently programmed Auto-Off setting

will display flashing.

The example assumes the Auto-Off function was OFF.

4) Use the TEST (Scroll) key to scroll through the choices.

In this example the Auto-Off function will be set to 1 hour.

5) When the desired choice is shown, Press TARE (Select)

to select it.

Pushing TARE (Select) places the displayed setting as the Auto-Off mode,
and exits back to the Main Setup Menu.

6) The next Main Menu item, “Unit” will appear. Either

select another Setup procedure with the TEST (Select)

key, or return to weighing mode by pushing ZERO

(Exit).

UNITS

The MSI-9300 will display and convert weight in pounds or kilograms. The TEST/USER key can be set to

switch between lb and kg if desired. If only 1 weight unit is needed, use this procedure to set the desired unit.

To Setup the Weight Unit

1

Func

2

TEST

a-Off

2

TEST

Unit

3

T

TARE

Unit

lb

4

TEST

Unit

kg

5

T

TARE

totaL

6

0

ZERO

to exit

6

TEST

to select other Main

Setup Menu items.

1) Start the Setup Mode using the procedure on page 12.

2) Use the TEST (Scroll) key to scroll to “Unit”.

3) With the display reading “Unit” press the TARE (Select)

key. The currently programmed Unit setting will display

flashing.

4) Use the TEST (Scroll) key to switch between kg and lb.

In this example the unit will be changed to kg.

5) When the desired choice is shown, Press TARE (Select)

to select it.

Pushing TARE (Select) sets the weight unit, and exits back to the Main Setup
Menu.

6) The next Main Menu item, “Total” will appear. Either

select another Setup procedure with the TEST (Select) key,

or return to weighing mode by pushing ZERO (Exit).