Page 4 MSI-9300 Crane Scale™

User Guide

MSI-9300 Porta-Weigh+ Crane Scale

The Battery Access Plate and

the Sealed Lead Acid Battery are

potential falling hazards. When

opening the battery access, be

sure to hold the battery to prevent

it from falling. This battery contains

Lead and should be recycled when

it has reached its end of life.

shackle or too large a hook to interface with the MSI-9300. This can cause off center loading and stress points

that will reduce the life of the MSI-9300 lifting eye or hook. Use the appropriate interface hardware for the

capacity of the scale. If your interface hardware does not fi t properly, MSI can supply the MSI-9300 with

oversize lifting eyes or shackle interfaces. If the crane hook is too large to fi t in the lifting eye with single point

interface, then install the scale using adaptive rigging.
If multiple attachments are needed, use a shackle or ring to attach the multiple lines to thus keeping a single

point attachment to the scale. Single point attachments are necessary to ensure the safety and accuracy of the

scale system.
Regular maintenance inspections of the lifting system should be performed to ensure safety. Pay particular

attention for signs of stress on any element in the load train.

BATTERY REMOVAL & REPLACEMENT

1) Turn the crane scale Off.
2) With one hand, hold the battery access to prevent it from falling.
3) Rotate the two cam-latch knobs counter-clockwise until the plate latches disengage.
4) Carefully back the plate out of the battery well.
5) Release the battery retaining strap.

Battery Access Plate

Cam-Latch Knobs

12V Sealed Lead Acid Battery

MSI P/N D00599-0004