Chapter 3 - Printer Operation

3.5.2 Standard Calibration

The Standard Calibration can be performed using the DMXConfig Utility, (see section 3.4 for more

information on DMXConfig) and using the front panel buttons (see Appendix C for more
information).
On display equipped printers the Standard Calibration routine can also be initiated

via the printer’s menu, see section 4.5. Once you have installed the DMXConfig utility and the

printer is properly loaded with media:

1. Connect the host to the printer with a

serial or parallel cable.

2. Turn on the printer.


3. Launch the DMXConfig utility.

4. Query the printer by using the ‘Query

Printer’ toolbar button (top-left). This will

connect to the printer and get the current

printer settings.



5. Select the “Sensor Calibration” Tab and

then click the “Media Calibration Wizard”

button. When prompted click “OK” to start

the calibration wizard.





6. The Calibration Wizard will now prompt

you to ‘Load Stock’. Be sure the media is

properly loaded in the printer. Close the

printhead and click “OK”.