Manual Media Sensor Calibration

The Manual Media Sensor Calibration procedure should be used in cases where the printer

continues to suffer from media sensing problems after performing or attempting to perform the

Auto Media Sensor Calibration.

;

Before calibrating, be sure the media sensor is set for the appropriate media type, also, ensure that
the Printhead Carrier Assembly is latched down and the cover is closed.

To manually calibrate the media sensor:

1. Hold the

CANCEL

button and power-up the printer. Continue to hold the button until the

STOP

light turns off; then release the button. Next, press and hold the

FEED

button,

continue to hold the button until the

STOP

light turns on; then release the button.

2. Remove all the material from the media sensor, close the Printhead Carrier Assembly, and

then press the

CANCEL

button. The printer will flash the

ERROR

light as it analyzes the

no media condition.


3. Position the backing material or the black (reflective) mark in the media sensor, close the

Printhead Carrier Assembly, and then press the

FEED

button. The printer will flash the

ERROR

light as it analyzes the top of form mark.

4. Place the media with the backing attached (if any) in the media sensor, close the

Printhead Carrier Assembly, and then press the

PAUSE

button. The printer will flash the

ERROR

light as it analyzes the material.


5. Simultaneously and briefly press the

PAUSE

+

CANCEL

buttons to accept the calibration

for “test” and exit the

. One of the following lights will flash five

times to denote the result of the manual calibration attempt:

STOP

light = Successful calibration. Proceed to Step 6.

ERROR

light = Unsuccessful calibration. Retry the procedure beginning at Step 1.

6. Use the

FEED

button (feeds a label), and the

CANCEL

button (prints a test label) to test the

current calibration.

;

If you wish to discard the changes and revert back to the previous calibration simply turn off the printer
before Step 7.


7. Now save the changes and resume

by pressing the

PAUSE

+

CANCEL

buttons

simultaneously and briefly. Wait until the

STOP

light goes off.