Units = .01 inch) – Rice Lake Datamax M-Class User Manual

Page 32

Advertising
background image

24

M-Class

13) TOF DELTA

Sets the minimum media sensor
change required to signify a label
gap or mark.

Possible Values:

Range: 0 – 50; nominal = *10
(Units = .1 volt)

14) TOF LOW

Sets the minimum media sensor
reading for paper (gap/notch) or mark
(reflective).

Possible Values:

Range: 0 – 50; nominal = *0
(Units = 0.1 volt)

15) LABEL WIDTH

Sets the label width.

Possible Values:

Range: 75 – 426; default = *426

(Units = .01 inch)

16) SCALABLE FONT

Sets the number of memory blocks
to allocate for scalable fonts.

Possible Values:

Range: 0 – 128; default = *64
(Units = 4K Bytes)

17) INTERNAL MODULE

Sets the number of memory blocks to
allocate for the internal RAM module.

Possible Values:

Range: 0 – 128; default = *128
(Units = 4K Bytes)

18) LABEL ALIGNMENT

Sets the label alignment method

(see

Section 4.6)

.

Possible Values:

YES (user manually determines

‘ALIGN LENGTH’)

AUTO (printer determines ‘ALIGN

LENGTH’)

*

NO

(no Label Alignment

used)


19) ALIGN LENGTH

Leading edge distance of two successive labels.
Must be entered if ‘LABEL ALIGNMENT’ is set
to Yes (see Section 4.6).

Possible Values:

0 – 999; default =100*
(Units = .01 inch)

20) OPTION CONTROL

Sets label stopping (and in certain cases the starting) location for
different printer configurations.

Possible Values:

* AUTO (Automatically sets the stop location. Installed options

will be ‘auto-sensed’ and the appropriate stop position
will automatically be set. Host commands are ignored.)


HOST

(Sets stop position according to options installed. If no
options are installed the printer sets stop location to the
next label’s start of print. Host commands will
override.)