7 diagnostics – Rice Lake Datamax M-Class User Manual

Page 67

Advertising
background image

M-Class

59

5.1.7 Diagnostics

HEX DUMP MODE

Most commonly used for troubleshooting. Prints data and instructions received from
the host rather than interpreting them as label formats; see Section 7.2.

ENABLED

Prints raw ASCII data received from the host rather than executing the commands.

DISABLED

Executes and prints label formats (normal operating mode).

OPTIONS TESTING

Allows or performs diagnostics of specific options within the printer.

TEST PRESENT SENSOR

Performs a functional test of the present sensor.

TEST CUTTER

Performs a functional test of the cutter.

PERFORM TEST
1 TIME

The test will cycle the selected number of times (1, 10, or 100) with the results
displayed following each attempt.



PRINT TEST RATE (min)

000 (0-120)

The number of minutes to delay between the printing of batches of Quick Test
Labels.

SENSOR READINGS

Analog Sensor readings are displayed.

THR TRAN RIBM 24V PS HD RANK
255 255 255 255 255 255 255


Live sensor values are displayed. Maximum values are shown in this example,
where:

THR = thermistor sensor;
TRAN = transmissive (gap) media sensor (REFL is shown if the SENSOR TYPE is
set to ‘reflective’);
RIB M = ribbon motion sensor;
24V = 24 volt DC power supply sensor;
PS = Present sensor;
HD = head-down sensor; and,
RANK = the value of the printhead ranking resistor.

RIBBON

SENSOR LIMITS

Displays ribbon sensor ADC low and high values used for motion detection.

RIBBON ADC LOW HIGH

070 164

Approximate default values are shown here (actual values will vary).