1 ac wiring, Ac wiring – Rice Lake SURVIVOR LaserLight Series Stop/Go Remote Displays - Installation & Operation Manual User Manual

Page 10

Advertising
background image

6

LaserLight Installation and Operation Manual

2.4.1

AC Wiring

The LaserLight power supply can run on either 115 or 230 VAC. The AC wiring is run through the cord grip to a
3-position AC terminal block bracket on the inside of the enclosure (shown in Figure 2-5). This bracket can be
removed by loosening the two standoffs and lifting it off. It can then be lowered and pulled outside of the enclosure
to ease wiring connections.

Figure 2-5. Inside Enclosure Backplate Diagram

Refer to the following table for AC wiring connections.

Ensure that a ground wire is attached to the grounding stud located on the enclosure backplate (see
Figure 2-5).

3-pin Terminal Block on Enclosure Back

To Power Supply

To Power Supply

Pin

Wire

Color

Pin

UL Approved Unit

1

Neutral

Blue or White

1

N

2

Hot

Brown or Black

2

L

3

Ground

Green or

Green/Yellow

Ground Tab

Table 2-1. AC Wiring Connections

Grounding
stud

Important