5 traffic light option, 1 dry contact wiring, Dry contact wiring – Rice Lake SURVIVOR LaserLight Series Stop/Go Remote Displays - Installation & Operation Manual User Manual

Page 30

Advertising
background image

26

LaserLight Installation and Operation Manual

4.5

Traffic Light Option

The Laserlight 4-SG remote display also comes with a traffic light option that uses 4

"

display digits in the 6

"

enclosure. The traffic light is factory configured to be controlled with serial commands (as described in Section 3.7
on page 20), but can be controlled by using dry contact switches: one switch or two switches. The following photo
illustrates the location of the traffic light board and the wiring for it and table 4-3 illustrates the wiring from the
traffic light board to J1 on the LaserLight CPU board.

Figure 4-4. Back of the LaserLight 4-SG Remote Display Showing CPU Board Location and Traffic Light Option

Wiring the traffic light board is explained below.

4.5.1

Dry Contact Wiring

The Dig 0 and Dig 1 pins on the traffic light board (pin 2 and pin 3 on connector J1 respectively) have pull up
resistors so that the operation of the traffic light can be controlled by switching the Dig 0 or Dig 1 (or both) to
ground.

A reset to the Laserlight CPU board will set the D0 and D1 pins on the Laserlight CPU (pins 5 and 6 on J1) to a
high pulled up state therefore, the default state of the traffic light will be a stop light (red).

Signal

Traffic Light Board

Location J1

Laserlight CPU Board

Location J1

Corresponding

Wire Color

5 VDC

1

4

Red

DIG O

2

5

Green

DIG 1

3

6

White

GND 4

7

Black

Table 4-3. Traffic Light Wiring

J1 Location
on the
Laserlight
CPU board

J1 location
on the traffic
light option
board

Note