1 display, 2 digital outputs, 3 digital inputs – Rice Lake SURVIVOR LaserLight Series Stop/Go Remote Displays - Installation & Operation Manual User Manual

Page 22: 4 loop back, 5 version, Display, Digital outputs, Digital inputs, Loop back

Advertising
background image

18

LaserLight Installation and Operation Manual

3.4.1

Display

When this feature is enabled, all LEDs remain lit until the

ENTER

button is pressed (Figure 3-2 11).

3.4.2

Digital Outputs

When enabled, this feature provides a way to view the different states of the digital outputs or the stop/go option if
installed.Use left and right arrows to increment/decrement and display the states LL, LH, HL, and HH which are
digital values of the 2 ports.

The following table lists the relay terminology and digital signal level terminology of each command.

Press the right button again to display LL and the stop/go option will show no light at all.

Press the right button again to display LH and the stop/go option will show a green arrow.

Press the right button again to display HL and the stop/go option will show a green circle.

So when HH is selected, the stop/go option will show a red circle.

3.4.3

Digital Inputs

When enabled, the digital inputs displays the current values read from the digital inputs.

3.4.4

Loop Back

When enabled, this feature provides a loop-back self test for use in diagnosing serial communications errors. The
loop-back self test checks the function of the remote display serial port by sending and receiving data to itself. The
following table shows the required connections.

If Port 1 receives nothing from Port 0 for three seconds, the following message is displayed on the remote display:

Fail 1

If Port 0 receives nothing from Port 1 for three seconds, the following message is displayed on the remote display:

Fail 2

If communications are successful between the two, the following message is displayed:

Pass

3.5

Version

When

Version

is selected from the main menu choices (Figure 3-8), the current software version is shown on the

remote display.

Figure 3-8. Version Menu

Dig Out 1

Dig Out 0

Stop/Go Signal

L

L

Off

L

H

Green Arrow On

H

L

Green Circle On

H

H

Red Stop

Relay On/Off Terminology

L = ON = 0V

H = OFF = +5V

Table 3-7.

Port 0 TR

Port 1 RCV

Port 1 TR

Port 0 RCV

VERSION

CONFIG

SERIAL

TEST

VER

Advertising