LaserLight Installation and Operation Manual

3.7.3

Display Message Command Format (Matrix Display):

3m8 and 3m12 remotes.

|<AA><DM>|<Timeout>|<Flash>|<Slide On>|<Scroll>|<Scroll Count>|<Data>!

where:

| = Pipe character (0x7C)

AA = Two byte address, ASCII digits

DM = Two byte command, ASCII characters

| = Pipe character (0x7C)

<Display Timeout> = Milliseconds to display the message (N/A for scroll). 32,767 (32 seconds) is the maximum
timeout. Anything above that number indicates an indefinite display.

| = Pipe character (0x7C)

<Flash> = “Y” or “N”

| = Pipe character (0x7C)

<Slide On> = “Y” or “N”

| = Pipe character (0x7C)

<Scroll> = “Y” or “N”

| = Pipe character (0x7C)

<Scroll Count> = Number of times to scroll the message or “A” for annunciator msg cmd (learn enable = OFF)

| = Pipe character (0x7C)

<Data> = Text to display

! = Exclamation point character (0 x 21)

Examples:

Scroll the message “Rice Lake Weighing Systems” 2 times

|00DM|0|N|N|Y|2|Rice Lake Weighing Systems!

Slide on and flash the message “DRIVE AHEAD” for 5 seconds

|00DM|5000|Y|Y|N|0|DRIVE AHEAD!

Command

Description

DM

<Data> is the 6 character message to display. If less than 6 characters, send spaces so it equates to 6
characters. Otherwise, some data may not be overwritten.
Example: |00DMSTOP !

GT

Get time and date. Information gathered is sent back to the indicator so that both the remote display and
indicator match. This is not displayed on the remote display.
Example: |00GT!

ST

Set time and date. Note that two spaces are required between time and date entries.
Example: |ST08:00:00 2003-01-31!

DI

Get digital input state

DO

Get digital output state

GR

Get relay state. Relay 0-3, 0=Off=LL, state 1=LH, state 2=HL, state 3=On=HH.

SR

Set relay state (output relays only). Relay 0-1, state 1=On & 0=Off.

GB

Get the number of 5 x 7 Max6953 boards (0 = 7-seg, 2, 3 = 5 x 7)

GV

Get the version number

DC

Dump configuration parameters (for testing purposes only)

TP

Temperature adjustment. Allows +/- 5% degree adjustment

Time and date is sent from the remote display depending on the current remote display time and date format:
Time and date are sent to the remote display in ISO format.
USA Format: HH:MM:SS AM/PM MMM/DD/YYYY
ISO Format: HH:MM:SS YYYY-MM-DD
If the real time clock is disabled in the remote display, an error message is sent back.