Unit Options (08H)

Unit Options
(08H)

The Unit Options command allows you to individually tailor how the RF3880
adapter operates, in either initiator or target mode, with each SCSI device on
the bus.

Usually these options need be set only once, at power-up, to create the proper
operating environment. Each unit you need to set-up requires a separate Unit
Options command.

Command

Format

The Parameter Block for the Unit Options command looks like this:

Description of

Fields

Each of the fields of the Parameter Block are described below:

Command Identifier

This field is used if you are issuing the Unit Options command through the
structure of a Command List. It is used to identify the Status block returned
from the command. It should be a unique value.

Adapter ID

This command performs no action on a specific SCSI device. It is a Board-
control command and so this field must be FFH.

Unit SCSI ID

This field must contain a number from 0 - FH representing a SCSI device on
the bus. Do not use the RF3880 adapter SCSI ID you assign with the General
Options command.

Address

Offset

Byte Memory Address

Offset + 0

Offset + 1

Offset + 2

Offset + 3

00H

Command Identifier

04H

Disconnect Time-out

Unit SCSI ID

Adapter ID = FFH

08H

Select Time-out

Retry Control

Retry Limit

0CH

Reserved

Reserved

Sense Count

Unit Flags

10H

Command = 08H

Reserved

14H

Sense Byte #

Sense Byte #

Sense Byte #

Sense Byte #

18H

Sense Byte #

Sense Byte #

Sense Byte #

Sense Byte #

Table 74: Unit Options Command Parameter Block