Table 101: extended board options field – Ciprico Rimfire 3880 User Manual

Page 166

Advertising
background image

21020285 D

User’s Guide

Chapter 7 Board-control Commands

Page 7 - 42

Extended Board Statistics (16H)

Options

This field has the following format and bit meanings:

CLR Clear

- This bit allows you to clear the internal statistic values currently

stored. (Statistics returned by both the 06H and 16H commands will be cleared.)
It is useful if you wish to keep track of statistics during a specific period. The
only other time statistic values get cleared is during adapter reset.

0

Command is used to return internal statistics to specified system memory

address.
1

Command is used to clear the internal statistics table.

FMT Format

- This bit determines whether the data returned from this

command will include information about all possible SCSI ID’s (16) or will
retain compatibility with previous adapters that were limited to 8 ID’s on a bus.
This bit is ignored if the CLR bit is set.

0

Use 8 ID format.

1

Use 16 ID format.

Command Code

The value for this field will always be 16H to indicate an Extended Board
Statistics command.

BITS

7

6

5

4

3

2

1

0

0

FMT

CLR

Table 101: Extended Board Options Field