Step 4: Apply power and observe LEDs

Page 3 - 13

Error

Conditions

The amber LED is used to indicate an error condition. These are the conditions
indicated by the amber LED:

BLINKS

- This indicates that the adapter has had a self-test failure.

STAYS ON SOLIDLY

- This indicates that the board has had a catastrophic

error during operation such as bus error or timeout. The Status port will contain
an error code that details the type of failure that occurred. These error codes are:

Code

Name

Description

10H

Bad PBIN or SBOUT

Value

The Command List PBIN or SBOUT value exceeded the
value set for PBNUM or SBNUM.

11H

State wrong for Start/

Stop Command List

command

The code is returned under these conditions:

Start Command List

command issued a command list is

already active.

Stop Command List

command issued when no command

list is presently active.

Command List Channel Attention

issued when no

Command List is active.

12H

Target Mode Error

A

Target Mode Selection Area Read

Channel Attention

issued when no selection are was written by adapter.

14H

Software VMEbus

Timeout

The adapter times each of its VMEbus transfers; it will report
this if a VMEbus transfer takes too long to complete. This

can occur for transfers of parameters as well as data.

15H

VMEbus Error Occurred

A VMEbus error was detected while the adapter was
transferring either parameters or data.

96H

Internal Firmware Error This error code indicates that a Firmware error was detected

during the execution of a command.

Table 15: Status Port Catastrophic Error Codes