Extended board statistics (16h), Command format, Table 100: extended board statistics parameter blo – Ciprico Rimfire 3880 User Manual

Page 165: Description of fields

Advertising
background image

User’s Guide

21020285 D

Chapter 7 Board-control Commands

Extended Board Statistics (16H)

Page 7 - 41

Extended
Board
Statistics (16H)

The RF3880 adapter keeps track of several types of board statistics. With the
Extended Board Statistics command you can retrieve the extended set of
statistics kept by the adapter. The statistics are valid only as long as power is
kept to the system. This command reports the statistics by recording them in
the area of system memory specified in the command Parameter Block; this
statistics structure is returned in addition to the normal Status Block.

You can clear the internal statistics table at any time by issuing the command
with the CLR bit of the Options field set. No data transfer occurs when the CLR
bit is set.

Command

Format

The Parameter Block format for the Extended Board Statistics command looks
like this:

Description of

Fields

Each of the fields of the Parameter Block are explained below:

Command Identifier

This field is used to identify the Status Block associated with a Parameter Block.
It must be a unique value.

Adapter ID

This field must be set to FFH.

Address Modifier

This is the value to be used by the adapter as an Address Modifier when writing
extended statistics to memory. This field is not used when the CLR bit is set.

VME Memory Address

This is the system memory address at which you wish to have the adapter place
the Extended Statistics Data Structure. This field is not used when the CLR bit
is set.

Address

Offset

Byte Memory Address

Offset + 0

Offset + 1

Offset + 2

Offset + 3

00H

Command Identifier

04H

Reserved

Addr. Mod.

Adapter ID = FFH

08H

VME Memory Address

0CH

Reserved

10H

Command = 16H

Options

Reserved

14H

Reserved

18H

Reserved

Table 100: Extended Board Statistics Parameter Block