Extended Unit Options (18H)

Page 7 - 45

Extended Unit
Options (18H)

This command, in either initiator or target mode, is designed as an enhancement
to the Unit Options command. The primary difference between the commands
is the opportunity to select 16 bytes of Sense Data to be returned per unit, instead
of the eight offered in the Unit Options command.

Another difference is that the Extended Unit Options for the SCSI device are
built into a Data Structure whose address is simply passed in the command.

Command

Format

The format of the Extended Unit Options command is as follows:

Description of

Fields

Each of the fields of the Parameter Block are described below:

Command Identifier

The Command Identifier field is used to identify the Status Block associated
with a Parameter Block. It must be a unique value.

Adapter ID

This is a Board-control command. The value in this field must be FFH.

Address Modifier

This is the value to be used by the adapter on the Address Modifier lines when
reading the Extended Unit Options Data Structure from memory.

VME Memory Address

This is the system memory address at which you have built the Extended Unit
Options Data Structure.

Command Code

The value for this field will always be 18H to indicate a Extended Unit Options
command.

The format of the Data Structure to be used for the Extended Unit Options
command is illustrated on the following pages.

Address

Offset

Byte Memory Address

Offset + 0

Offset + 1

Offset + 2

Offset + 3

00H

Command Identifier

04H

Reserved

Addr. Mod.

Adapter ID = FFH

08H

VME Memory Address

0CH

Reserved

10H

Command = 18H

Reserved

14H

Reserved

18H

Reserved

Table 103: Extended Unit Options Parameter Block