Chapter 4 Command Operation

Some Example Single Commands

Page 4 - 15

Example

2:Inquiry

Pass-through

Command

This example describes the issue of a Initiator Pass-through command. The
SCSI Inquiry command is fully described in the SCSI specification.

This example shows you how to use the Single Command structure to issue an
Initiator Pass-through command.

1.

The set-up of a Pass-through command is the same as for a Board-
control command. You must select a portion of system memory for the
Single Command structure. You will need 52-bytes of space to hold the
Parameter Block, Interrupt and Reserved fields, and the Status Block
that make up a Single Command structure. For this example we’ll use
the same memory address.

Example Memory Address = 822F4H

2.

Fill in the Parameter Block information. (Detailed Parameter Block
information for Initiator Pass-through commands is given in Chapter 5.
For information about the SCSI Inquiry command, you must reference a
SCSI specification or drive manual.)
These are the Parameter Block values for this example:

Command Identifier = 822F4H

- Even though the Status Block is part of

the Single Command structure and easily identified it is good to provide a value
here in order to be consistent with Command List structures. The value chosen
is the address of the Single Command structure.

ID = 01H

- Indicates to the RF3880 adapter that this Pass-through command

should be directed to device ID 1.

Address Modifier = 3DH

- This value indicates Standard Supervisory Data

Access mode will be used to execute the Inquiry command.

Flags-1 = 0

- This byte is used to control aspects of command operation. None

of the features are enabled for this command.

Flags-2 = 0

- This byte offers further command control options. None of the

additional features are enabled for this example.

VME Memory Address = 99450H

- System Memory address to which the

Inquiry data will be returned.

Transfer Count = 24H

- This value is the number of bytes of data that will

be transferred for this command. The Inquiry data returned by this device is
contained in 36 (24H) bytes.

Address

Offset

Byte Memory Address

Offset + 0

Offset + 1

Offset + 2

Offset + 3

00H

Command Indentifier = 000822F4H

04H

Flags-2 = 0

Flags-1 = 0

Addr Mod = 3DH

ID = 01H

08H

VME Memory Address = 00099450H

0CH

Transfer Count = 24H

10H

Command = 12H

LUN = 0

Reserved = 0

Reserved = 0

Inquiry

6-Byte

Command

Descriptor

Block

14H

Allocation = 24H Flag/Link = 0

0

0

18H

0

0

0

0

Table 23: Example Pass-through command PB