Figure 11-7) – CANOGA PERKINS 9145EMP NID Software Version 4.0 User Manual

Page 152

Advertising
background image

Service OAM

9145EMP NID Software User’s Manual

SOAM Configuration

137

NOTE: You can perform system-level configuration before or after you configure Maintenance
Domains or other entities.

4. On the SOAM System Level Configuration screen (Figure 11-7), type 1 and press Enter.

5. Use the Space bar to select Enabled or Disabled and press Enter. If Service OAM

procedures are disabled for the system, no Service OAM packets are captured and
processed. Instead, all Service OAM packets received by the 9145EMP NID are
transparently forwarded, using the same rules as for data plane traffic.

6. To select a Chassis ID Format, type 2 and press Enter. Select one of the following

settings:

MAC Address, and press Enter. The Chassis ID value is read only. You cannot
change the value on this screen.

Network Address, and press Enter. The Network Address value is read only. You
cannot change the value on this screen.

Locally Assigned, and press Enter. This selection allows you to enter a custom
string.

Figure 11-7 SOAM System Level Configuration screen

7. If you chose Locally Assigned in step 4, type 3 and press Enter. The Chassis ID Value

field is highlighted.

8. Enter string in the Chassis ID Value field and press Enter.

Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2011
9145EMP-761-4-0 V40.43 Canoga 9145EMP 32 device 11:20:59
-----------------------SOAM SYSTEM LEVEL CONFIGURATION--------------------------

1) Service OAM: Enabled

SENDER ID TLV
2) Chassis ID Format: 7 - Locally assigned
3) Chassis ID Value:
Management Address Domain: SNMPoverIPv4
Management Address: 172.16.140.100

Sender ID TLV applicability:
4) CC: Disabled 5) LBM: Disabled 6) LTM: Disabled

7) PORT ID TLV configuration


Select [1-7]:

------------------------------------Messages-----------------------------------