CANOGA PERKINS 9145EMP NID Software Version 4.0 User Manual

Page 30

Advertising
background image

System Configuration

9145EMP NID Software User’s Manual

IP/SNMP Agent Configuration

15

rudimentary performance testing from subscriber/user VLANs without compromising network
security.

To configure the parameters, type the corresponding number and press Enter. Enter data or
press the Space bar to view the configuration choices for the parameters described below.

Separate tagging configuration is necessary for User Side and Network side ports. All ports on
the user side must share the same tagging configuration.

Figure 3-4 Auxiliary IP Configuration screen

1. Auxiliary IP Address Sets the 9145EMP Auxiliary IP Address.

Auxiliary Subnet Mask Sets the 9145EMP Auxiliary IP Subnet Mask.

2. Inband Auxiliary Port Describes the Auxiliary IP address ports. Options are: USR 1,

USR 2, USR 3, USR 4, Network Port, or Disabled.

3. Auxiliary VLAN Tagging on Network ports Describes the tagging mode for the frames

sent and received when the Auxiliary IP address is configured on the Network Port.
Options are: Untagged, S-Tagged, S-C (double) Tagged, S-T (tunnel) tagged, and S-T-C
(triple) tagged.

4. Auxiliary C-VLAN ID on Network ports Sets the C-VLAN ID value (between 1 and

4094). Valid if the Auxiliary VLAN Tagging mode on Network ports is set to S-C Tagged or
S-T-C Tagged. The value defaults to zero if any of the other types of tagging are selected.

5. Auxiliary T-VLAN ID on Network ports Sets the T-VLAN ID value (between 1 and

4094). Valid if the Auxiliary VLAN Tagging mode on Network ports is set to S-T Tagged or
S-T-C Tagged. The value defaults to zero if any of the other types of tagging are selected.

6. Auxiliary S-VLAN ID on Network Sets the S-VLAN ID value (between 1 and 4094). Valid

if the Auxiliary VLAN Tagging mode on Network ports is set to S-C tagged (Double


Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2011
9145EMP-761-4-0 V40.43 Canoga 9145EMP 32 device 11:20:59
------------------------------AUXILIARY IP CONFIGURATION-----------------------

1) Auxiliary IP Address 010.0012.013.014
Auxiliary Subnet Mask 255.255.255.000
2) Auxiliary Port No Ports Allowed
3) Aux VLAN Tagging on Network ports S-T-C Tagged
4) Aux C-VLAN ID on Network ports 100
5) Aux T-VLAN ID on Network Ports 200
6) Aux S-VLAN ID on Network ports 300
7) Aux VLAN Tagging on User ports Untagged
8) Aux C-VLAN ID on User ports 0
9) Allow Any Vlan Disabled
10) Aux IP Rate Limiting Enabled

Select [1-10]: