Important, Low voltage direct wired peak control, Back of heater – Steffes 2106 Owner & Installers Manual User Manual

Page 14

Advertising
background image

Multiple Unit - low Voltage Connections Direct Wired Controls

Figure 8

Notes: 1. Connecting the low voltage hot (blue) wire

from multiple heaters to a single control

switch may cause damage to the system. In

multiple heater applications, connect the

wires as shown for proper operation.

2. In this configuration, one outdoor sensor is

needed for each heater installed.

Installation 2.07

2100 Series

Single Unit - low Voltage Connections Direct Wired Controls

Figure 7

loW VoltAge Direct WireD PeAK control

If using the low voltage control option, the heater is direct wired to

the power company's peak control switch. Field connections from the

switch are made to the heater’s low voltage wiring harness through

the low voltage raceway. These wires are also accessible from inside

the electrical compartment. Class II (low voltage) wiring should never

enter a line voltage area of the heater, including its umbilical cord.
Some power companies also use anticipated (pre-peak) signals. If applicable to your installation, the control switch

providing the pre-peak signal can also be connected directly to the heater with low voltage wire. Refer to the Low

Voltage Connections Direct Wired Controls Diagram (Figure 7) for reference to peak and anticipated peak low

voltage connections.

If routing low voltage wire near line

voltage conductors, shielded wiring

must be used.

IMPORTANT

Control Switch

Peak

Outdoor Sensor

Gray

Gray

Blue/White

Blue

BACK OF

HEATER

BA

CK

OF

HE

ATE

R

Blue/White (Peak)

Blue (Hot)

Black (Common)

Blue (Not Used)

BA

CK

OF

HE

ATE

R

Blue/White

Outdoor Sensor

Black

#2

#1

Gray

Gray

Gray

Gray

Peak Control Switch

Outdoor Sensor

(See Note 2)

(See Note 1)

(See Note 2)

Low Voltage

Junction Box

Low

Voltage

Junction

Box