rOOm TemPerATure COnTrOl

The room temperature set point is adjusted by pressing the up arrow to increase or the down arrow to decrease the

set point. When the heater senses a heat call, the variable speed blower is energized and circulates room air through

the brick core. This heated air is discharged into the room to maintain the desired temperature. In an effort to keep

the room temperature constant, the blower automatically adjusts to the appropriate speed and may continue to

operate after the set point has been reached.
If the owner prefers to monitor room temperature at a point away from the heater, an optional remote room

temperature sensor is available. A remote room sensor also provides more even heat distribution in an area where

more than one heater is installed. It is recommended to use the optional remote room sensor in applications where

the right side panel has less than a 12" clearance or where the right side of the heater is exposed to abnormal

temperature conditions such as drafts from a door or window.

STArTIng THe SYSTem

On start-up, odors and/or small volumes of smoke relating to first time operation of the heating components may

occur. There also may be an odor associated with dust accumulation if the heater is shut down for an extended period

of time. Allow the heater to charge to its highest heat storage level (full core charge) to expel these odors. Refer also

to maintenance and cleaning section of this manual.

Turning the heater "OFF" suspends all functions of the heater. To turn the heater "OFF", use the down arrow to

decrease the room temperature set point until "OFF" is displayed on the faceplate. To turn the heater "ON", use the

up arrow to adjust room temperature set point to the desired temperature.

The heater MUST remain "ON" if being used to supply a peak control signal to other

controlled loads.

BrICK COre CHArge COnTrOl

The amount of heat stored in the heater’s brick core can be regulated by automatic or manual charge control. The

heater is factory preset for automatic charge control regulation. If manual charge control is desired, the heater must

be reconfigured at the time of installation.

AutomAtic chArge control

With automatic charge control, the brick core charge level is regulated automatically in relation to outdoor

temperature and the heating requirements. An optional outdoor sensor or Steffes power line carrier (PLC) system

is required. The outdoor sensor or PLC system monitors outdoor temperature and provides this information to the

heater. The heater responds by storing heat in the brick core accordingly. No user interface is required to adjust the

brick core charge level.

mAnuAl chArge control

If manual charge control is being used, the brick core charge level must be regulated by the user. During the heating

season, the user needs to periodically adjust the brick core charge level setting in relation to outdoor temperature and

the heating requirements of the area. To configure the heater for manual charge control, refer to the Configuration

Menu (Page 2.10).
Adjusting the Brick core charge level (manual charge control)

Step 1

Press and release the M button until "CORE" is displayed.

Step 2

Press the up or the down arrow button to adjust the brick core charge level set point. The charge level to

be targeted can be set to any value from 0 to 100 percent.

Step 3

Once the desired charge level is set, press the M button once to return to normal display mode.

Operation 1.02