mAnuAl reSeT lImIT COnTrOlS

2100 Series

Appendix A.05

InTernAl lOW vOlTAge WIrIng DIAgrAm

Clearance Violation limit: Located inside the heater in the upper front corner of the

electrical compartment. Activation of this control would be indicated by the display

scrolling “core” “fail” and would indicate that the heater has malfunctioned. Contact

service technician to troubleshoot and repair the root cause of the condition.

Core Charging high limit: Located inside the heater at the back of the electrical

compartment. Activation of this control would be indicated by the display scrolling

“core” “fail” and would indicate that the heater has malfunctioned. If the heater is

equipped with a 1/8” limit reset hole in the rear, upper location in the heater’s side

panel, this limit can be reset. If the heater is not equipped with this remote reset feature

or if there has been multiple trip conditions, contact service technician to troubleshoot

and repair the root cause of the condition.

Discharge Air high limit: The discharge air high limit is located in the lower left

portion of the grill area and can be accessed through the grill. Activation of this control

would be indicated by a blank display screen. This control can be reset by pressing the

button on the limit control located just inside of the discharge air grills. If this control

activates multiple times, contact a qualified service technician for repairs.

The discharge air high limit, the core charging high limit, and the clearance violation limit

switches are all manual reset limit controls installed for safety purposes. If one of these

limit controls opens, it must be manually reset before operating the heater. To reset the limit

controls, press and release the reset button located in the middle of the control.

Risk of electric shock. Do not disassemble the

heater. There are no user serviceable parts inside.

WARNING

Gray

Gray

Purple

Purple

Blue

Yellow

Blue/White

M

Black

Green

Red

Red

Yellow

Yellow

-

+

+

-

A

P

M

M

Outdoor Sensor

Built-in or Remote Mount

Automatic Charge Control

Room Sensor

Outdoor Sensor

Room Sensor

Anticipated Peak Control (Specialty Applications)

Low Voltage Common (Grounded)

Room Temperature Set Back

Brick Core Sensor (Thermocouple)

Output Sensor (Thermocouple)

Peak Control

Low Voltage Hot