Appendix, Specifications – Steffes 2106 Owner & Installers Manual User Manual

Page 19

Advertising
background image

Appendix

A

SPeCIFICATIOnS

* Refer to the Unit Identification Label on lower left side panel for data specific to your heater. In standard

configuration, the heater can be connected to 208V or 240V. Rated input at 208V is 75% of rated 240V

input. If full rated input is required in 208V applications, contact the factory.

MODEl

2102

2102

2103

2104

2105

2106

plug-in

Length - inches

30

30

37

44

51

58

Height - inches

24.5

24.5

24.5

24.5

24.5

24.5

Depth -

inches

(w/out wall bracket)

10.5

10.5

10.5

10.5

10.5

10.5

(w/wall bracket)

12

12

12

12

12

12

Number of Bricks

16

16

24

32

40

48

Number of Brick Boxes

4

4

6

8

10

12

Weight of Heater - lbs

105

91

112

126

145

164

Weight of Bricks - lbs

176

176

264

352

440

528

Installed Weight - lbs

281

267

376

478

585

692

*Element Voltage

120

240 (std)

240 (std)

240 (std)

240 (std)

240 (std)

208 & 277 opt 208 & 277 opt 208 & 277 opt 208 & 277 opt 208 & 277 opt

*Inputs Available - kW

1.32

2.4, 3.0, 3.6

3.6, 4.5, 5.4

4.8, 6.0, 7.2

6.0, 7.5, 9.0

7.2, 9.0, 10.8

*Blower/Control Voltage

115

230 (std)

230 (std)

230 (std)

230 (std)

230 (std)

120 or 208 opt 120 or 208 opt 120 or 208 opt 120 or 208 opt 120 or 208 opt

Blower Wattage

Minimum

30

30

30

30

30

30

Maximum

120

120

120

120

120

120

Storage Capacity

kWh

13.5

13.5

20.25

27

33.75

40

BTU

46,062

46,062

69,093

92,124

115,155

136,480

2100 Series