Warning, Installer's final check-out procedure – Steffes 2106 Owner & Installers Manual User Manual

Page 18

Advertising
background image

Installation 2.11

2100 Series

InSTAller'S FInAl CHeCK-OuT PrOCeDure

With the heater de-energized, hinge the right side panel open

(Page A.08). Complete the system check-out below:
Step 1 Inspect all field connections to ensure they are tight and

that all wires are routed correctly.

Class II (low voltage) wiring or any wiring not rated

for line voltage should never be installed in a line

voltage area.

Step 2 Check the damper system to ensure the damper operates

freely and that there is no debris in this area, which could

inhibit its operation. To do so, slowly press the damper

lever extending from the damper downward. Be careful

not to bend the damper actuator. If the damper is not

free, remove the blower and clean any debris from the

damper.

Step 3 Make sure the blower operates by adjusting room

temperature set point above the actual room temperature.

Step 4 With the system in an off-peak (charge) mode, initiate

the charge control override (Page 1.03).

Step 5 Check for proper amperage draw on the charging

circuit(s). Use the Charge Circuit Amperage Draw Chart for reference to the correct amperage of the

specific heater being installed.

Step 6 Verify that the heater receives and responds to the utility peak control device and that all other system

controls are operating properly.

Step 7 Place grill slats in position, if removed.

Grill slats should bow up to direct

airflow up, away from the floor.

Step 8 Place the right side panel back into

position and secure.

Step 9 Return the control circuit board to its

original position and install the painted

front panel.

Step 10 Verify that configuration settings are

correct for the application. Refer to the

Configuration Menu (Page 2.10).

On start-up, odors and/or small

volumes of smoke relating to

first time operation of the heating

components may occur.

Step 11 Make certain all fuses and/or circuit

breakers are labeled in the distribution

service panel as this system may be connected to more than one branch circuit.

Step 12 Present owner with the manual and warranty information. The owner's registration card must be

completed and returned to Steffes Corporation to ensure warranty coverage. The owner should retain

the top portion of the card for their records.

INPUT WATTAgE

VOlTAgE

AMP DrAW

1.32 kW

120

11.00

2.4 kW

240

10.00

3.0 kW

240

12.50

3.6 kW

240

15.00

4.5 kW

240

18.75

4.8 kW

240

20.00

5.4 kW

240

22.50

6.0 kW

240

25.00

7.2 kW

240

30.00

7.5 kW

240

31.25

9.0 kW

240

37.50

10.8 kW

240

45.00

ChArgE CIrCUIT AMPErAgE DrAW ChArT

(AMP draw is calculated by taking the total input wattage

divided by the input voltage. Allow +/- 5% tolerance at

nominal input voltage.)

WARNING

Risk of fire. Can cause injury

or death. ETS devices run

for long periods of time at

high electrical loads. Poor

or marginal connections will

cause the connections to

overheat and fail.

Risk of electric shock. Can

cause injury or death. This

heater may be connected to

more than one branch circuit.

Disconnect power to all circuits

before installing or servicing.

DO NOT remove the painted

front panel while energized.

Equipment must be serviced by a

qualified technician.