PlaceMent anD clearance reQuireMentS

The system dimensions and required clearances MUST be taken into

consideration when choosing its location within a structure. (See

Figure 2 for dimensions and clearance requirements.)

The best installation location for the system is in a space requir-

ing heat so some amount of the heating requirements can be satis-

fied through static dissipation from the warm outer panels of the

ThermElect Hydronic system. In situations where the system is not

installed in an area it is intended to heat (i.e. garage or storage area),

it is important to account for the heat lost through static dissipation

by making proper adjustments when sizing the system.

This area must remain free of debris and most importantly the

room air should be maintained at less than 85

o

Fahrenheit. Area

may require ventilation. Refer to Specifications (Pages A.01-A.02).

It is the responsibility of the installer and system designer to provide

this ventilation.

In addition to the physical space requirements, the weight of the system must also be taken into consideration when

selecting the installation surface. A level concrete floor is the designed installation surface, but most well supported

surfaces are acceptable. If unsure of floor load capacity, consult a building contractor or architect.

Special requirements must be considered if placing the system in a garage or other area where com-

bustible vapors may be present. Consult electrical, building, and fire prevention codes.

SySTEM REQUIREMENTS

FIgURE 2

dIMENSIONS

Some electrical codes may require a greater front and/or left side

clearances depending on operating voltages and other factors.

CLEaRaNCES

Back = 8 inches

Bottom = 1 inch (from combustible material)

Right Side = 12 inches

Top = 8 inches (from combustible material)

Left Side & Front = 36 inches (for ease in servicing)

Adhere to clearances and provide appropriate ventilation to maintain

no greater than 85

o

F air temperature in area where system is installed.

Risk of fire. Can cause injury or death.

Violation of the clearance require-

ments or failure to provide proper

ventilation can cause improper op-

eration of the system. Maintain the

placement and clearance require-

ments as specified and provide

ventilation as necessary.
Moving the system after install

may result in equipment damage.

Do NOT move system from original

installed location.

WARNING

34"

80K

W

STO

RA

GE

MO

DU

LE

40 1

16

9180 - 98"

9150 - 77"

51"

36" MINIMUM

CLEARANCE

36" MINIMUM

CLEARANCE

1" CLEARANCE

REQUIRED

8" MINIMUM CLEARANCE

12" MINIMUM

CLEARANCE

36" MINIMUM CLEARANCE

8" MINIMUM CLEARANCE

12" MINIMUM

CLEARANCE

installa

tion

installa

tion

T

herm

e

lecT

h

ydronic

i

nSTallaTion

3.03

i

nSTallaTion

3.02

T

herm

e

lecT

h

ydronic

Advertising
This manual is related to the following products: