external Duct SenSor

The optional external duct sensor (Order Item #1041536)

provides the ability to monitor the duct temperature at an area

beyond fresh air makeup and/or beyond other devices and

regulate the discharge air temperature accordingly.

The duct sensor feature is enabled if the 4 bit is set in Location

53 (L053). Once enabled, the ThermElect Hydronic system

monitors temperature at both the duct sensor and the output

sensor during Y, W, or E calls from the thermostat.

Static Heat recovery unit

During operation of the ThermElect Hydronic, there is some static

dissipation that comes off of the warm outer panels. The Static Heat

Recovery unit (Order Item #1302110) moves this heat from the

ThermElect Hydronic system to an area requiring heat. Utilizing

this option can maximize efficiency when the system is installed in

an unheated area.
With the Static Heat Recovery unit installed, the ThermElect Hydronic system can

be set up to monitor temperature at the control board and/or in the brick core. If

either of these temperatures reach a point greater than the preset point, the blower

is the Static Heat Recovery unit is energized and draws heat from inside the painted

outer panels of the ThermElect Hydronic system and delivers it to the desired area

of the structure.

liftinG HanDleS

Optional lifting handles (Order Item #1302120) are available to aid in moving the

ThermElect Hydronic system into its final location.

Scr controller

The Steffes SCR (Solid State Relay Panel) is an optional control device used with

the Steffes ThermElect (8100 and 9100 Series) and Comfort Plus Commercial

(6100 and 7100 Series) Heating Systems (Order Item #1301016). It utilizes SCR

technology to enable more precise balancing of a building’s overall electric load by

varying the amount of total element input that can be energized in a Steffes furnace at

any given time in relation to the maximum allowable building load. The Steffes SCR

optimizes a building’s power quality and control.

The SCR Controller can only accept input signals from the Steffes furnace but it can

respond to all types of control inputs to include 4 – 20 Milliamp, 1 – 5 Volt DC, electric

meter pulsing, Bacnet or any building energy management system. With the 4 – 20mA

or 1 – 5 volt DC signals, the SCR will provide an output directly proportional to the

input signal. 4mA signal produces 0% output while 20mA signal products 100% output.

With the utility pulse meter input, the SCR output percentage will automatically adjust

to maintain a total maximum system load as dictated by the furnace’s set-up. With a

Bacnet, the furnace can be commanded to varying input levels remotely.

SENSOR

AIR HANDLER

9100 SERIES

THERMELECT

WATER

COIL

SCR CONTROLLER

LIFTINg HaNdLES