Warning, Safety precautions, Built-in safety devices – Steffes 9180 User Manual

Page 3

Advertising
background image

Safety PrecautionS

Fully assemble the system and load ceramic heat storage

1.

brick prior to energizing the system.

Pressure relief valve must be installed prior to operation of

2.

the system.

Use or storage of explosive or flammable gasses or liquids

3.

within close proximity of the system presents a hazard.

Clearance requirements are critical to safe operation of the

4.

system. Follow all requirements specified in this manual

(Page 3.03).

Keep the top of system clear.

5.

Use caution when working around the heating system as inlet

6.

and outlet piping can be very hot.

De-energize all branch circuits before servicing. This heating

7.

system may be connected to more than one branch circuit.

Installation of and/or service to this heating system should be

8.

performed by a qualified technician in accordance with in-

formation contained herein and with national, state, and local

codes and requirements.

Repeated error codes on the system display (pages A.10 –

9.

A.13) indicate a need for service by a qualified technician.

Special requirements must be considered if placing the sys-

10.

tem in a garage or other area where combustible vapors may

be present. Consult local, state and national codes and regula-

tions to ensure proper installation.

Built-in Safety DeviceS

The ThermElect Hydronic heating system incorporates safety devices to ensure normal operating temperatures are

maintained. The chart below describes these safety devices.

T

herm

e

lecT

h

ydronic

S

afeTy

i

nformaTion

dEVICE

location

on system

Core Charging High

Limit Switches

(Auto Reset)

These limit switches monitor the core and top temperatures.

If normal operating temperatures are exceeded, the system

will display "CORE FAIL" and the elements will not be

allowed to operate.

Right side of system.

This linear limit switch monitors the temperature of the wa-

ter in the exchanger and interrupts power to the core blower

if a water temperature of 250

o

F/121

o

C is exceeded. If this

limit switch opens, contact a qualified service technician.

Heat Exchanger

Limit Switch

(Manual Reset)

Behind front lower

painted panel. Reset

button visible in lower

right front corner.

This linear limit switch monitors the temperature of the

water in the exchanger and interrupts power to the core

blower if a water temperature of 225

o

F/107

o

C is exceeded.

Outlet Water

Temperature Limit

Switch (Auto Reset)

Behind front lower

painted panel.

Pressure Relief Valve

Factory provided,

field installed to outlet

of heat exchanger.

If the water pressure exceeds maximum psig, the pressure

relief valve opens. Once water pressure of less than maxi-

mum psig is achieved, the valve closes.

FUNCTION

WARNING

Hazardous Voltage: Risk of electric

shock, injury, or death. This system

may be connected to more than one

branch circuit. Disconnect power

to all circuits before installing or

servicing. Installation of and/or

service to this equipment MUST be

performed by a qualified technician.
Risk of explosion. Operating the

system without the pressure relief

valve properly installed can cause

an explosion. Connect the pressure

relief valve in a vertical, upright po-

sition with the supplied fittings. DO

NOT modify this assembly. DO NOT

cap, plug, or otherwise obstruct the

outlet of the pressure relief valve.
Risk of fire. Violation of the clear-

ance requirements can cause im-

proper operation of the equipment.

Maintain the placement and clear-

ance requirements specified.
Hot Surface. Plumbing and other

surfaces can be hot. Use caution

when working near the system.