Holtgreven GSE-665 User Manual

Page 43

Advertising
background image

35

5

C

HAPTER

5: A

CCUMULATION

M

ODE

60 Series controllers offer three main memory registers into which weighing
data may be accumulated. The three registers are the Gross Total, Net Total
and the Quantity Total.

P

ERFORMING

A

CCUMULATIONS

First, enter the desired “Accumulation Mode” either by pressing the
[SELECT] key until one of the Accumulation Modes appears on the display
or key in one of the accumulation parameters directly. Refer to Table 4:
Accumulation Mode Numbers
on page 36. Once in an Accumulation Mode,
press [UNITS] + [SELECT] on the Model 460 or [.] [ENTER] on all other
60 Series indicators to add the displayed value to the accumulated total.
Accumulate operations are motion delayed. If motion is occurring when an
accumulation is requested, the Mot'n Delay prompt is displayed until motion
ceases. If motion does not stop, press [CLR] to abort the accumulation.

There are six Accumulation Modes with corresponding Mode Numbers as
shown in Table 4. When an accumulation is made, both the Gross and Net
totals are affected. After an accumulation occurs, these values are frozen at
their new accumulate total values until the Gross Weight returns to zero. The
weight must return to zero before another accumulation is allowed. At that
time, these values again resume their active state. This feature prevents
double accumulations. A CLEAR WGHT prompt appears to warn of such
situations.

I

NITIALIZING

A

CCUMULATION

T

OTALS

The Accumulation Registers may be reset to a new number. This would
permit you to enter a total from the previous day or shift to continue the
accumulation, or to reset the number to “0”. Access the Accumulation Mode
by keying in the single or two-digit mode number from Table 4 and pressing
[SELECT] (not available on the Model 460). If the mode is one of the pre-
programmed selectable modes simply toggle to the corresponding mode
using the [SELECT] key. Key in the desired reset value and press
[ENTER]. You will then be prompted to confirm the accumulation
modification by a display of MOD AC? for 1 second followed by ENTER
=MOD
. Press [ENTER] to confirm the change or any other key to abort the
modification of the accumulation total.