H

ARDWARE

P

ROBLEM

E

RROR

M

ESSAGES

17 A/D BAD!

The processor has detected a problem with the
A/D chip. Contact your GSE distributor.

18 BufSzMax!

The accumulative total buffer size for both the
TX and RX buffers of all four COMM ports is
4096 bytes. Displayed If entries to the “buffer
size” parameters (P207-P208) exceed this total.

19 x06\x44\x61ta&Stop Certain combinations of protocol are not

available. The protocol combination selections
are in P201, P202 and P203. This error occurs
if an illegal protocol combination is selected.
Refer to the Communications chapter in the
technical reference manual.

20 Deflt A/D

This message appears for 1 second. It will be
displayed if the A/D calibration data gets
corrupted. Contact your GSE distributor.

21 WriteNVErr

Error reading data from the EEPROM. Possible
U16 and U17 problem.

22 ReadNVErr

Error writing data to the EEPROM. Possible
U16 and U17 problem.

23 CheckNVPar

Supplementary error message for above errors.

24 NVParFull!

The setup being attempted requires more
EEPROM than is currently installed.

25 DefltSetup

Upon power-up the indicator has not found the
proper codes. Therefore all parameters have
been reset to factory default values.

26 Bad Setup

The stored data has a checksum error. Check all
parameters or re-load setup.

27 RE-BOOT!

The indicator cannot use the EEPROM for data
storage, so it is attempting to power-up again to
cure the problem.