6 0 S

E R I E S

I

N D I C A T O R S

60

28 NoRAMAVAIL

The current setup requires more RAM than is
currently installed. Either contact your dealer or
the manufacturer.

29 PIN error

This message will appear on power-up or setup
if the E

2

is corrupted in the PIN section. Check

E

2

for problems. The access code is defaulted to

the manufacturer (GSE) access code. Also
check Error 11.

C

ALIBRATION

E

RROR

M

ESSAGES

30 F.S.>MAX!

The entered calibration weight, together with the
currently applied signal, indicates that the full
scale signal will be greater than the allowed
maximum of the indicator. Verify that correct
entries have been made for the capacity, P110,
and for the calibration weight. If all appears
correct, refer to the use of the information
parameter P61100, and determine the output (in
mv / volt) of the connected load cell.

31 F.S.<.1mVv

The entered calibration weight, together with the
currently applied signal, indicates that the full
scale signal will be less than the allowed
minimum of the indicator. Verify the proper
entries for the capacity, P110, and for the
calibration weight. If all appears correct, refer to
the use of the information parameter, P61100
and determine the output (in mv / volt) of the
connected load cell.

32 ADD MORE!

The applied weight during calibration was less
than 0.1% of capacity. More weight than this is
required. Refer to P61100 if this is incorrect.

33 ReCALReq'd

The just completed calibration may not yield
accurate results due to either the cal weight
being less than 5% of capacity or this was the
first calibration of this platform to this indicator
and therefore the coarse gain was adjusted by
the indicator.