562) - f – Holtgreven GSE-665 User Manual

Page 50

Advertising
background image

6 0 S

E R I E S

I

N D I C A T O R S

42

Note: if the weight is greater than the high limit then the prompt OVER” is displayed.
If the weight is less than the low limit the prompt “UNDER” is displayed. If the
weight is between the high and low limits then prompt “GOOD” is displayed.

B

ATCHING

O

PERATION

(465,560

AND

562) -

F

ILL

S

ETTING SETPOINTS

,

PREACT

,

AND DRIBBLES

1. Press

[TARGET] or [F2] prompt = “current setpoint value + SP 1”.

2. Key in Setpoint value.
3. Press

[ENTER] prompt = “ current setpoint value + PAct.”.

4. Key in Preact value (if enabled), zero (0) for no preact.
5. Press

[ENTER] prompt = “current setpoint value + Drib”.

6. Key in Dribble value (if enabled), zero (0) for no dribble.
7. Repeat steps 2 – 6 for each setpoint your systems has.
8. Systems returns to previous display mode.

B

ATCHING

1. Press

[ZERO] to zero the indicator

2. Press

[F1]. Fill until the target is met. “Done” will be displayed when

cycle completes

3. Empty the scale



Advertising